When MINIO_TRACE_DIR is provided, create a new log file and store all
HTTP requests + responses data, body are excluded to reduce memory
consumption. MINIO_HTTP_TRACE=1 enables logging. Use non mem
consuming http req/resp recorders, the maximum is about 32k per request.
This logs to STDOUT, body logging is disabled for PutObject PutObjectPart
GetObject.
Duration for which a lock was held can be computed from the `Since`
field of `OpsLockState`. It is the difference between current time and
time at which the namespace lock was held. This change avoids
superfluous instrumentation.
This PR is for readability cleanup
- getOrderedDisks as shuffleDisks
- getOrderedPartsMetadata as shufflePartsMetadata
Distribution is now a second argument instead being the
primary input argument for brevity.
Also change the usage of type casted int64(0), instead
rely on direct type reference as `var variable int64` everywhere.
`principalId` i.e user identity is kept as AccessKey in
accordance with S3 spec.
Additionally responseElements{} are added starting with
`x-amz-request-id` is a hexadecimal of the event time itself in nanosecs.
`x-minio-origin-server` - points to the server generating the event.
Fixes#3556
- Add a lockStat type to group counters
- Remove unnecessary helper functions
- Fix stats computation on force unlock
- Removed unnecessary checks and cleaned up comments
This is implemented so that the issues like in the
following flow don't affect the behavior of operation.
```
GetObjectInfo()
.... --> Time window for mutation (no lock held)
.... --> Time window for mutation (no lock held)
GetObject()
```
This happens when two simultaneous uploads are made
to the same object the object has returned wrong
info to the client.
Another classic example is "CopyObject" API itself
which reads from a source object and copies to
destination object.
Fixes#3370Fixes#2912
- abstract out instrumentation information.
- use separate lockInstance type that encapsulates the nsMutex, volume,
path and opsID as the frontend or top-level lock object.
These messages based on our prep stage during XL
and prints more informative message regarding
drive information.
This change also does a much needed refactoring.
- Instrumentation for locks.
- Detailed test coverage.
- Adding RPC control handler to fetch lock instrumentation.
- RPC control handlers suite tests with a test RPC server.