The new call combines GetObjectInfo and GetObject, and returns an
object with a ReadCloser interface.
Also adds a number of end-to-end encryption tests at the handler
level.
Allow minio s3 gateway to use aws environment credentials,
IAM instance credentials, or AWS file credentials.
If AWS_ACCESS_KEY_ID, AWS_SECRET_ACCSES_KEY are set,
or minio is running on an ec2 instance with IAM instance credentials,
or there is a file $HOME/.aws/credentials, minio running as an S3
gateway will authenticate with AWS S3 using those one of credentials.
The lookup order:
1. AWS environment varaibles
2. IAM instance credentials
3. $HOME/.aws/credentials
4. minio environment variables
To authenticate with the minio gateway, you will always use the
minio environment variables MINIO_ACCESS_KEY MINIO_SECRET_KEY.
Two handlers are added to admin API to enable profiling and disable
profiling of a server in a standalone mode, or all nodes in the
distributed mode.
/minio/admin/profiling/start/{cpu,block,mem}:
- Start profiling and return starting JSON results, e.g. one
node is offline.
/minio/admin/profiling/download:
- Stop the on-going profiling task
- Stream a zip file which contains all profiling files that can
be later inspected by go tool pprof
The test TestServerTLSCiphers seems to fail sometimes for
no obvious reason. Actually the test is not needed
(as unit test) since minio/mint tests the server's TLS ciphers
as part of its security tests.
Fixes#5977
Currently, one node in a cluster can fail to boot with the following error message:
```
ERROR Unable to initialize config system: Storage resources are insufficient for the write operation
```
This happens when disks are formatted, read quorum is met but write
quorum is not met. In checkServerConfig(), a insufficient read quorum
error is replaced by errConfigNotFound, the code will generate a
new config json and try to save it, but it will fail because write
quorum is not met.
Replacing read quorum with errConfigNotFound is also wrong because it
can lead, in rare cases, to overwrite the config set by the user.
So, this commit adds a retry mechanism in configuration initialization
to retry only with read or write quorum errors.
This commit will also fix the following cases:
- Read quorum is lost just after the initialization of the object layer.
- Write quorum not met when upgrading configuration version.
ReadFile RPC input argument has been changed in commit a8f5939452959d27674560c6b803daa9,
however, RPC doesn't detect such a change when it calls other nodes with older versions.
Hence, bumping RPC version.
Fixes#6458
It was expected that in gateway mode, we do not know
the backend types whereas in NAS gateway since its
an extension of FS mode (standalone) this leads to
an issue in LivenessCheckHandler() which would perpetually
return 503, this would affect all kubernetes, openshift
deployments of NAS gateway.
This commit fixes an AWS S3 incompatibility issue.
The AccessKeyID may contain one or more `/` which caused
the server to interpret parts of the AccessKeyID as
other `X-Amz-Credential` parameters (like date, region, ...)
This commit fixes this by allowing 5 or more
`X-Amz-Credential` parameter strings and only interpreting
the last 5.
Fixes#6443
This commit will print connection failures to other disks in other nodes
after 5 retries. It is useful for users to understand why the
distribued cluster fails to boot up.
Enhance a little bit the error message that is showing
when access & secret keys are not specified in the
environment when running Minio in gateway and server mode.
This commit also removes a redundant check of access/secret keys.
This commit fixes the Manta gateway client creation flow. We now affix
the endpoint scheme with endpoint URL while creating the Manta client
for gateway.
Also add steps in Manta gateway docs on how to run with custom Manta
endpoint.
Fixes#6408
This commit fixes are regression in the server regarding
handling SSE requests with wrong SSE-C keys.
The server now returns an AWS S3 compatable API error (access denied)
in case of the SSE key does not match the secret key used during upload.
Fixes#6431
This PR adds two new admin APIs in Minio server and madmin package:
- GetConfigKeys(keys []string) ([]byte, error)
- SetConfigKeys(params map[string]string) (err error)
A key is a path in Minio configuration file, (e.g. notify.webhook.1)
The user will always send a string value when setting it in the config file,
the API will know how to convert the value to the appropriate type. The user
is also able to set a raw json.
Before setting a new config, Minio will validate all fields and try to connect
to notification targets if available.
Currently Go http connection pool was not being properly
utilized leading to degrading performance as the number
of concurrent requests increased.
As recommended by Go implementation, we have to drain the
response body and close it.
Removing an empty directory is not working because of xl.DeleteObject()
was only checking if the passed prefix is an actual object but it
should also check if it is an empty directory.
soMaxConn value is 128 on almost all linux systems,
this value is too low for Minio at times when used
against large concurrent workload e.g: spark applications
this causes a sort of SYN flooding observed by the kernel
to allow for large backlog increase this value to 2048.
With this value we do not see anymore SYN flooding
kernel messages.
ListMultipartUploads implementation is meant for docker-registry
use-case only. It lists only the first upload with a prefix matching
the object being uploaded.
* Revert "Encrypted reader wrapped in NewGetObjectReader should be closed (#6383)"
This reverts commit 53a0bbeb5b.
* Revert "Change SelectAPI to use new GetObjectNInfo API (#6373)"
This reverts commit 5b05df215a.
* Revert "Implement GetObjectNInfo object layer call (#6290)"
This reverts commit e6d740ce09.
An issue was reproduced when minio-js client functional
tests are setting lower case http headers, in our current
master branch we specifically look for canonical host header
which may be not necessarily true for all http clients.
This leads to a perpetual hang on the *net.Conn*.
This PR fixes regression caused by #6206 by handling the
case insensitivity.
This combines calling GetObjectInfo and GetObject while returning a
io.ReadCloser for the object's body. This allows the two operations to
be under a single lock, fixing a race between getting object info and
reading the object body.